Updated as of:
|
03/08/16
|
|
|
|
|
|
|
|
|
Trunkline 2015 Pipeline Outage and
Maintenance Summary
|
Listed below is a summary of the
planned outages that could affect capacity or impact any receipt/delivery
locations during the TGC 2015 outage season.
This schedule is not a complete list of all outages and is subject to
change as the season progresses to reflect any project delays, cancellations
or additions. Additionally,
anticipated impact and restrictions are subject to change.
*All scheduled dates represent gas days as defined in the Trunkline
tariff to mean a period of twenty-four consecutive hours, beginning and
ending at 9:00 a.m. (Central Clock Time).
|
*
Indicates revision
|
|
|
|
|
|
|
*Outage
Completed
|
|
|
|
|
|
|
|
|
Revised
|
Start Date
|
End Date
|
Prev. Start Date
|
Prev. End Date
|
Location
|
Unit(s)
|
Maintenance
|
Anticipated Impact
|
Meter Impact
|
*
|
06/04/2015
|
06/18/2015
|
|
06/15/2015
|
Longville
|
100-3 Line
|
Anomalies
|
Doornbos - Union Gas Operating shut-in
|
Location #82854
|
|
08/11/2015
|
08/14/2015
|
|
|
Longville
|
Station
|
Painting
|
Ragley Exchange - Transco shut-in
|
Location
#80277
|
|
08/28/2015
|
09/11/2015
|
|
|
Beeville
|
Eagle Plant
|
Pigging - GV
18 to Eagle Plant
|
Operators could
experience higher daily line pressures and pressure fluctuations
|
None
|
|
08/28/2015
|
09/03/2015
|
|
|
Beeville
|
Station
|
Pigging - GV
18 to Beeville Station
|
Operators
could experience higher daily line pressures and pressure fluctuations
|
None
|
|
09/14/2015
|
09/18/2015
|
|
|
Tuscola
|
Station
|
Electrical
|
IT and
Secondary Out of Path into Zone 2 are subject to scheduling reductions
|
Zone 2
Deliveries
|
*
|
09/14/2015
|
09/18/2015
|
09/01/2015
|
09/04/2015
|
Centerville
|
300-1 Line
|
Valve
Replacements
|
Bridgeline@Patterson, SONAT@Shadyside, Enlink LIG@Patterson Shut-in
|
Location(s)
80578, 81738, 80488
|
*
|
09/21/2015
|
12/11/2015
|
|
10/30/2015
|
Ambia
|
Unit 6104
|
Station
Upgrades
|
IT and
Secondary Out of Path into Zone 2 are subject to scheduling reductions
|
Zone 2
Deliveries
|
*
|
09/22/2015
|
10/20/2015
|
|
10/09/2015
|
Ambia
|
Station
|
Station
Upgrades
|
IT and
Secondary Out of Path into Zone 2 are subject to scheduling reductions
|
Zone 2
Deliveries
|
*
|
09/28/2015
|
10/08/2015
|
09/21/2015
|
09/25/2015
|
South Texas
|
GV16 - GV18
|
Anomalies
|
20% Pressure Reduction
|
None
|
|
10/19/2015
|
11/06/2015
|
|
10/30/2015
|
North Judson
|
Unit 6202
|
Station
Upgrades
|
IT and
Secondary Out of Path into Zone 2 are subject to scheduling reductions
|
Zone 2
Deliveries
|
|
11/06/2015
|
11/20/2015
|
|
|
South Texas
|
|
Valve
Replacement
|
See Critical
Posting for Affected Meters
|
See Critical
Posting
|
*
|
11/17/2015
|
05/31/2016
|
|
03/01/2016
|
Longville
|
300-1/300-2 Line
|
Exposed Pipe/Anomaly Repairs/Testing
|
Woodbrook 36 No. 1
|
Location 82876
|